

- SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC GENERATOR
- SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC DOWNLOAD
- SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC WINDOWS
GF 01 (03 min, ): Negative Sequence Protection (46).Part F: Generator negative sequence protection GE 04 (09 min, ): Configuration and parameter settings of the pole slip function block.
SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC GENERATOR

GD 03 (02 min, ): PQ plane and RX plane.GD 02 (08 min, ): Generator Capability Curve.GD 01 (03 min, ): causes of loss of field, generator capability curve, end region heating, steady-state stability limit, under excitation limiter.Part D: Generator Under excitation / Loss-of -Excitation (ANSI 40 ) protection GC 03 (06 min, ): Configuration and parameter settings of the 100 stator earth fault function block.GC 02 (08 min, ): stator earth fault protection.GC 01 (06 min, ): why stator earth fault protection, 59N, 27TN, 100 % stator earth fault protection.Part C: Generator stator earth fault protection GB 04 (01 min, ): phase differential element.GB 03 (10 min, ): Configurations and parameters of the generator differential protection block.GB 02 (03 min, ): Principal of differential protection function.GB 01 (04 min, ): Review of the generator protection functions in Single line diagram.Part B: Generator differential protection GA 11 (10 min, ): theory of operation of synchronous AC Generator, typical generation systems, grounding strategies.GA 10 (06 min, ): testing of the directional directional in REG670.GA 09 (23 min, ): config and settings of the directional overcurrent in REG670.GA 08 ( 22 min, ): config and testing of the inverse time overcurrent in REG670.GA 07 (12 min, ): signal monitoring and troubleshooting technique.GA 06 (10 min, ): injecting signals and monitoring in the REG670 signal monitoring, config binary outputs.GA 05 (17 min, ): REG670 configuration (online, offline).GA 04 (18 min, ): REG670 configuration (online, offline).GA 03 (08 min, ): The review of REG 670 relay, the hardware structure of REG670, rearview and front view of REG670, main protection functions, backup protection functions, control & monitoring functions, REG670 templates (A20, B30, C30).GA 02 (12 min, ): stator winding faults, field winding or rotor circuit faults, abnormal operating conditions, the object of the protection system, generator protective relaying technology, multifunction generator protection systems (MGPS), numerical relays, generator ANSI codes, IEEE Recommendations for different Generator protection functions, an overview of different generator relays from different manufactures (ABB, Schneider, SEL, Siemens).GA 01 (10 min, ): Cylindrical and salient pole rotors, generator connections, normal Operation, abnormal Conditions, generator protection, function of a protection System, generator grounding techniques, fault Current Behavior of a synchronous generator.

Part A: Introduction, review the generator construction and protection
SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC DOWNLOAD
SYNOPSYS SYNPLIFY PRO FAILED TO EVALUATE GENERIC WINDOWS
